Characteristic and use

YR2 sequence motor from 4kw-500kw&comma 2&comma four&comma six&comma 8p&comma IP23 class F insulation
YR2 series &lparIP44 IP23&rpar motors are 3-section asynchronous motors with a wound rotor for standard employs&period They are the upgraded products of the latest layout in China&period of time The grade of electrical power and measurements for installment are in line with I&period E&period of time C&period CZPT standard&time period Their mutual relations are related to people of Product DIN 42679 of West Germany&comma by changing the rotor’s circumscribed resistance&comma the collection motors can purchase very good commence operate and modified speed in small scope&time period They are widely employed in start moment which is greater than that for squirrel cage&comma the potential of the electrified wire netting that is not enough to begin the squirrel cage rotor motor&comma extended and recurrent commence and in connecting the electric powered shaft to travel synchronously&interval
The series motors are sealed motors and the defense grade IP44 IP54 The rated frequency for the motors is 50Hz&semi While the rated voltage is 380-440v&interval The insulation is of Grade F and the procedure of this motor is S1&lparcontinous running&rpar&time period Relationship mode&colon &lpar3KW&period Y&rpar&semi Rotor Y&interval The collection motors have a lot of positive aspects these kinds of as high efficiency&comma powerful overloading power&comma minimal sound&comma tiny shock&comma dependable framework and lovely outer casing&period Specially the rotor parameter is united in China&comma so it really is convenient for buyers to trade or type a total set&interval Those who when chose the series motors of JRO2&comma JRO2L and CRO can use YR sequence &lparIP23&rpar motors which are much more suited if exported singly or in the type of a full set&time period

Motor Efficiency
Electrical power range&colon 4-500KW
Rated Voltage&colon 380V-440V
Pace&semi 3000rpm 1500rpm 1000rpm 750rpm 600rpm 500rpm
Protection Course&colon IP23
Ambient Temperature&colon -15° C~40° C
Altitude&colon Not exceed one thousand Meter
Rated Frequency&colon 50Hz&sol60Hz
Insulation Class&colon F
Temprature rise&colon B
Operating Duty&colon S1&lparContinuous&rpar
Link&colon CZPT-link for up to 3kW&semi Delta-relationship for 4kW and previously mentioned

Ordering Informations

1&period Make sure you point out the motor variety&comma rated output&comma rated voltage&comma rated frequency&comma synchronous velocity&comma Explosion proof Mark&comma mounting sort&comma rotation course&lparview from the shaft extension facet&rparUse of the environment&lparindoor or outside&rparIf the user havn’t point out the rotation and setting&comma normailly we consider is CW roration and utilised indoor&interval
two&period of time When person have particular requirments&comma For instance&colon Dispose the stator&comma bearing explosion evidence and bearing temperature sensors&comma space heater&comma Plateau use&comma specical frequency&comma mounting size change&comma unique output&comma the user should&comma buy can be verify right after signing the technical settlement with engneering section&period of time
three&period of time The catalogue is only fpr reference&comma and there could be variants&period
four&period of time This selection of motor can also be made into Variable-Frequency motors&comma the variety of frequency of which is -100HZ&comma the output and total proportions need to be confirm independently&period of time

ype kW Volts HZ RPM AMPS EF&percnt P&periodF&time period Tm Rotor Lp J kgm2 kg CZPTs
&lparDelta&rpar V I &lpardB&rpar DE NDE
200L1-4 eighteen&period5 400 fifty 1470 33&period9 90&period3 &period87 3 239&period4 47&period6 eighty five &period29 272 6312 6312
200L2-4 22 400 50 1470 forty 91 &period87 three 280&period9 48 85 &period32 286
225M2-4 thirty 400 50 1475 fifty two&period3 92&period2 &period89 three 350 fifty one&period5 87 &period63 376 6313 6313
250M1-4 37 four hundred fifty 1480 sixty seven ninety two&period2 &period86 3 290 seventy eight&period9 89 &period87 460 6314 6314
250M2-four 45 400 fifty 1480 eighty ninety two&period9 &period87 three 338&period7 81&period7 89 &period98 520
280S-four fifty five four hundred 50 1480 ninety seven 92&period6 &period88 3 466&period4 seventy one&period5 89 one&period86 655 6317 6317
280M-four 75 400 fifty 1485 131 93&period6 &period88 three 381&period7 118 ninety 2&period41 765
315S-4 ninety 400 fifty 1486 157 93&period8 &period88 three 334 159 ninety three&period97 1175 NU319 6319
315M-4 a hundred and ten 400 fifty 1486 189 94&period8 &period88 three 340 191 90 4&period59 1300
315L1-four 132 400 50 1488 226 94&period8 &period89 3 419 185 ninety three five&period33 1360
315L2-four one hundred sixty four hundred 50 1489 271 ninety four&period8 &period9 three 496 189 ninety four 6&period11 1450
355M1-4 two hundred four hundred fifty 1489 329 ninety five&period2 &period92 three 531 227 94 10&period03 1952 NU322 6322
355M2-4 250 four hundred 50 1489 410 95&period5 &period92 3 638 236 96 eleven&period33 2078
355L-four 280 four hundred 50 1490 456 95&period8 &period92 3 709 237 96 twelve&period47 2194
400L1-four 315 four hundred 50 1485 524 95&period1 &period905 2&period8 557 340 111 17&period85 3390 NU324 6324
400L2-four 355 400 fifty 1486 587 95&period2 &period905 two&period8 620 344 111 19&period34 3515
400L3-four 400 four hundred fifty 1487 659 ninety five&period4 &period905 2&period8 698 343 111 21&period11 3655
200L1-6 15 four hundred 50 980 29&period4 89&period7 &period82 2&period8 199&period3 forty eight 78 &period41 276 6312 6312
225M1-six 18&period5 400 50 980 35&period3 ninety&period4 &period84 two&period8 187 62&period5 80 &period65 335 6313 6313
225M2-6 22 four hundred 50 980 41&period6 91 &period84 two&period8 224 61 80 &period72 360
250M1-6 thirty four hundred fifty 985 55&period3 91&period4 &period85 2&period8 284&period7 sixty six&period3 80 1&period22 480 6314 6314
250M2-6 37 four hundred fifty 985 sixty nine 91&period9 &period84 2&period8 337&period9 68&period5 81 1&period35 520
280S-6 45 four hundred 50 985 eighty two 92&period5 &period86 two&period8 360&period9 77&period6 eighty two two&period41 645 6317 6317
280M-six fifty five four hundred 50 985 98 ninety three&period1 &period86 2&period8 486 70&period1 eighty two 2&period74 695
315S-six seventy five 400 50 990 135 ninety three&period5 &period86 2&period8 470 ninety eight 86 5&period48 745 NU319 6319
315M-six ninety 400 50 990 161 94&period1 &period86 two&period8 489 113 86 six&period25 1335
315L1-six 110 400 fifty 990 192 ninety four&period6 &period87 two&period8 485 one hundred forty 86 7&period3 1421
315L2-six 132 four hundred fifty 990 232 ninety four&period8 &period86 two&period8 477 a hundred and seventy 86 eight&period45 1430
355M1-6 one hundred sixty 400 fifty 992 281 ninety five &period86 2&period8 471 205 89 twelve&period28 1950 NU322 6322
355M2-6 200 four hundred fifty 993 346 ninety five&period5 &period87 2&period8 577 209 90 fourteen&period86 2164
355L-six 220 400 fifty 993 381 95&period5 &period87 two&period8 649 204 90 16&period71 2273
400L1-6 250 400 fifty 989 444 ninety four&period5 &period86 2&period6 446 337 108 20&period69 3345 NU324 6324
400L2-6 315 four hundred fifty 990 553 94&period8 &period86 two&period6 536 352 108 23&period73 3545
400L3-6 355 four hundred 50 992 627 95&period1 &period86 two&period8 670 315 108 28&period28 3835
200L-eight 11 400 50 730 23&period7 88&period4 &period75 2&period4 147&period3 47&period3 74 &period41 276 6312 6312
225M1-eight fifteen four hundred 50 735 31&period9 89&period7 &period75 two&period4 169 56 76 &period71 357 6313 6313
225M2-eight 18&period5 400 fifty 735 39&period1 90&period6 &period75 two&period4 211 54 seventy six &period83 387
250M1-eight 22 400 50 735 44&period5 ninety&period4 &period79 two&period4 213&period9 64&period9 seventy seven one&period18 480 6314 6314
250M2-eight thirty 400 50 735 sixty one&period5 91&period2 &period77 2&period4 274 68&period4 78 one&period4 520
280S-eight 37 four hundred 50 740 seventy four ninety one&period8 &period79 2&period4 281 81&period7 78 two&period36 645 6317 6317
280M-8 forty five 400 fifty 740 86 ninety two&period8 &period8 two&period4 357&period7 seventy seven&period7 eighty 3 735
315S-eight 55 400 50 742 104 93 &period8 two&period4 486 69 eighty one 5&period24 1050 NU319 6319
315M-eight seventy five 400 fifty 742 139 ninety three&period8 &period81 two&period4 498 91 83 6&period82 1386
315L1-8 ninety 400 50 743 172 ninety four&period1 &period8 2&period4 504 108 83 7&period82 1475
315L2-eight 110 400 fifty 743 209 94 &period81 two&period4 514 129 83 nine&period21 1485
355M1-8 132 four hundred fifty 743 246 ninety four&period4 &period82 2&period4 462 171 86 13&period24 1908 NU322 6322
355M2-eight 160 four hundred fifty 744 294 ninety four&period5 &period83 2&period4 562 a hundred and seventy 86 16&period05 2086
355L-eight 185 400 50 744 345 ninety four&period5 &period82 2&period4 655 168 86 seventeen&period84 2203
400L1-eight 200 four hundred fifty 740 404 ninety three&period8 &period76 3 464 257 102 eighteen&period9 3275 NU324 6324
400L2-eight 250 400 50 740 498 ninety four &period76 3 557 267 one hundred and five 21&period94 3470
400L3-eight 315 four hundred fifty 740 624 94&period5 &period76 three  
 
 